Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 766-771, 2019.
Article in Chinese | WPRIM | ID: wpr-750299

ABSTRACT

@#Objective    To investigate the effect of artificial colloid on coagulation function in pediatric patients weighing less than 5 kg with congenital heart disease during cardiopulmonary bypass in congenital heart disease surgery by using artificial colloid instead of human serum albumin. Methods    A total of 65 pediatric patients with weight less than 5 kg who underwent congenital heart disease surgery in our hospital from September 2016 to December 2017 were included in the study. They were randomly divided into two groups: an artificial colloid group (the experimental group, n=33) and a human serum albumin combined artificial colloid group (the control group, n=32). Perioperative hemoglobin concentration (Hb), blood products and hemostatic drugs used, postoperative coagulation function index and pleural fluid volume 24 hours after surgery were monitored. Results    There was no significant difference in perioperative Hb and chest tube drainage between the two groups. The platelet utilization rate in the experimental group was significantly lower than that in the control group (P<0.05). No significant difference was found in the dosage of other blood products and hemostatic drugs between the two groups during the perioperative period. There was no significant difference in coagulation parameters between the two groups before and after surgery (P>0.05). Conclusion    The use of artificial colloid as colloid priming solution during cardiopulmonary bypass has no adverse effect on coagulation function in pediatric patients weighting less than 5 kg with congenital heart disease.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 809-813, 2018.
Article in Chinese | WPRIM | ID: wpr-731944

ABSTRACT

@#Myocardial and cerebral protection are always the major concerns in neonatal aortic arch surgery. From the application of deep hypothermic circulatory arrest technology to continuous cardio-cerebral perfusion strategy adopted in many cardiac centers recently, each perfusion method has its own pros and cons, so there is no consensus on which one is the most suitable. This review aims to summarize the development and research progress of various perfusion methods, so that to provide a foundation for further development.

SELECTION OF CITATIONS
SEARCH DETAIL